Ground-Bearing Slabs
Reinforced slabs-on-ground for retail centres, offices, factories and showrooms, built to your engineer's design so they carry heavy commercial loads without cracking, settling or needing costly early repairs.
Ground-bearing and suspended concrete slabs for shops, offices, workshops and other commercial buildings.
Commercial concrete slabs in Dunedin carry some of the heaviest loads in the city, from retail centres and warehouses to offices, healthcare and education buildings. We build slabs that stay flat, strong and crack-controlled, with careful attention to ground conditions, reinforcement, joints and curing.
Dunedin's cold winters, steep sites and varied soils all affect how a slab should be designed and poured, so we plan each project around your engineer's drawings and the NZ Building Code. Our crews work closely with builders, project managers and developers to keep pours on program and inspections on track.
We stand behind every slab we pour. Whether you need a ground slab for a new warehouse or a suspended slab for a multi-storey build, we deliver reliable workmanship, clear communication and finished surfaces that suit your intended use from the first day of operation.
Reinforced slabs-on-ground for retail centres, offices, factories and showrooms, built to your engineer's design so they carry heavy commercial loads without cracking, settling or needing costly early repairs.
Formwork, reinforcement and placement for suspended floors, podiums and elevated decks, coordinated with propping, pump access and engineers so upper levels meet structural requirements on program.
Support for post-tensioned slab construction, including formwork, reinforcement and pour coordination with specialist stressing crews, helping engineers achieve longer spans, thinner slabs and structural performance on commercial buildings.
Crack repair, joint filling, grinding and slab replacement for ageing commercial floors, restoring flatness, strength and durability so your building stays safe, productive and compliant without full reconstruction.
Insulated, reinforced floors for cold stores, food facilities and temperature-controlled buildings, with vapour barriers and careful curing that protect against moisture, frost and thermal movement.
Clear communication with builders, engineers and certifiers, with inspections arranged before each pour, so your slab is delivered to program and handed over with test results and documentation.
A commercial slab has to carry heavy loads for decades, and Dunedin's cold winters, steep sites and varied soils make careful preparation just as important as the pour. We plan every project around your engineer's drawings and the NZ Building Code, so your slab performs long after handover. Our crews work closely with builders, project managers and developers, keeping pours on program and communication clear from tender to completion. We stand behind every slab. We treat your deadlines and budget as seriously as our own.
Get A Free Estimate
Flat, strong, crack-controlled slabs built to your engineer's design, delivered on program by an organised team that communicates clearly from the very first site meeting to final handover and sign-off.
Get A Free Commercial Concrete Slabs EstimateGround preparation, curing and cold-weather protection planned for frost, wet ground and changeable winter weather.
Reinforcement, joints and finishes built exactly to drawings, with inspections and test records at every hold point.
Clear communication and organised crews that keep your project moving and your site safe.
A commercial slab is the working surface of your building, so the rules behind it matter before any concrete arrives. In Dunedin, slabs must carry real loads from vehicles, shelving and equipment while coping with cold winters, wet ground and sloping sites. That is why thickness, strength, reinforcement and joint layout are set by an engineer rather than guessed on the day. Understanding the requirements early helps you budget accurately, avoid redesign and keep consent applications moving. Below we outline what typically applies to commercial slabs here, from specification and steel through to council consent, so you know what to expect from your project.
Ground-bearing commercial slabs typically range from 150 to 200 millimetres thick, using 25 to 32 megapascal concrete, though your engineer's design for loads sets the final specification.
Slabs use grade 500E reinforcement, with cover and joint spacing set under NZS 3101 and NZS 3109, controlling shrinkage cracking and protecting steel from Dunedin's freeze-thaw conditions.
Commercial slabs usually need building consent with engineer design, inspections and full documentation, plus Dunedin City Council requirements for stormwater, vehicle access, earthworks and site works.
Helpful guidance for planning a durable concrete project in Dunedin.
Ground-bearing commercial slabs typically range from 150 to 200 millimetres thick, using 25 to 32 megapascal concrete. The final thickness depends on the loads from vehicles, shelving and equipment, so your engineer's design sets the specification. Heavier use usually means a thicker slab, stronger concrete and more reinforcement in practice.
Commercial slabs usually need building consent supported by engineer design, inspections and full documentation. Dunedin City Council requirements for stormwater, vehicle access, earthworks and site works may also apply. Checking these early helps avoid redesign and keeps your consent application moving without unnecessary delays or last-minute surprises once work begins.
Price is driven by slab area and thickness, concrete strength, reinforcement and joint layout, plus site access, slope and ground preparation. Engineer design requirements, consent costs and pour timing also matter. A site visit and drawings allow a quote to reflect your actual loads and conditions, not assumptions or guesses.
Cold, wet conditions can slow concrete strength gain and increase the risk of freeze damage, so pours are planned around forecasts. Reinforcement cover and jointing are designed to cope with freeze-thaw exposure and control shrinkage cracking. Curing and protection may be needed, which can influence your programme and timing overall.
Tell us about your project and our local Dunedin team will come back with practical advice, clear pricing and a free, no-obligation quote, so you can move forward with confidence.
Get A Free Estimate